TRL 70B

FURMATS offer Fired Bauxite Based Brick including TRL 70B

PRODUCT DESCRIPTION

Fired Bauxite Based Brick

APPLICATION

HML

CONTROL PROPERTIES

CONTROL PROPERTIES  
   
CHEMICAL ANALYSIS (Calcined Basis)UNIT by wtVALUETEST METHOD
TypicalLimit
     
Al2O3%71≥ 70By XRF
Fe2O3%2.9≤ 3.0
     
PHYSICAL PROPERTIESUNITVALUETEST METHOD
  TypicalLimit
     
Bulk Densitygm/cc2610≥ 2600ISO 5017 : 1998
     
App. porosityVol.%21≤ 22.0ISO 5017 : 1998
     
CCSN/mm255≥ 45ISO 10059-2 : 2003
     
SUPPLEMENTARY PROPERTIES (FOR INFORMATION ONLY)   
   
     
PLC,1400°C/2hrs, Min/Max%1.53ISO 2478 : 1987 (L = V/3)
     
RUL(ta)°C1440≥ 1440DIN 51064
     
PCESK35≥ 35ISO 528 : 1983
     
INFORMATIVE PROPERTIES    
    
     
TiO2%3.85By XRF
SiO2%20.8
CaO%0.65
     
Control Dimensions AQL 6.5% for critical dimensions (ISO 5022 Table – 3)
     
Sampling/Acceptance ISO 5022, Table 4 or Table 10(AQL4%)
     
Shelf Life 36 months from the date of manufacture when stored under shed & free from moisture.

  Note: 1) The typical technical data shown are based on average results on production samples and are subjected to normal variation on individual tests. Hence, it cannot be taken as specification.

2) The above specification is valid for solid pressed standard items only

Scroll to Top